Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Insuf. card ; 15(3): 70-75, oct. 2020. ilus, tab
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1143100

RESUMO

Marco teórico. Con base en la teoría de los sistemas dinámicos, fue establecida una ley matemática exponencial que al ser aplicada a los sistemas cardíacos caóticos, permitió cuantificar estados de normalidad y enfermedad, siendo también posible encontrar el número total de dinámicas cardíacas a partir de esta comprensión matemática del fenómeno. En este estudio se evaluó la aplicabilidad clínica y utilidad diagnóstica de la ley exponencial en 300 registros electrocardiográficos continuos y estudios Holter, en 16 horas. Material y métodos. A partir de 300 registros electrocardiográficos continuos y estudios Holter, dentro de los cuales 50 presentaban diagnóstico convencional de normalidad y los restantes 250 algún tipo de patología, se construyeron los mapas de retardo para cada dinámica cardíaca. Seguidamente, se calculó la dimensión fractal y los espacios de ocupación de los atractores. Se realizó la evaluación matemática en 16 y 21 horas, mediante la ley exponencial, y se llevó a cabo la validación estadística. Resultados. Se obtuvo que los valores para la rejilla Kp entre 203 y 346 correspondían a normalidad, mientras que valores entre 35 y 197 correspondían a enfermedad, en 16 horas. El valor encontrado para el coeficiente Kappa fue de 1, la sensibilidad y especificidad fueron de 100%. Conclusiones. Se logró establecer que la metodología matemática permite realizar diagnósticos certeros en 16 horas, comprobándose su aplicabilidad en 300 registros electrocardiográficos.


Background. Based on the theory of dynamic systems, an exponential mathematical law was established that, when applied to chaotic cardiac systems, allowed to quantify states of normality and disease, being also possible to find the total number of cardiac dynamics from This mathematical understanding of the phenomenon, in this study, evaluated the clinical applicability and diagnostic utility of the exponential law in 300 continuous electrocardiographic records and Holter tests, in 16 hours. Methods. With 300 continuous electrocardiographic registers and Holter tests, of which 50 presented conventional diagnosis of normality and the remaining 250 some type of pathology, the delay maps were constructed for each cardiac dynamics. Next, the fractal dimension and the spaces of occupation of the attractors were calculated. It was made the mathematical evaluation in 16 and 21 hours, using the exponential law and the statistical validation was performed. Results. It was obtained that the values for the grid Kp between 203 and 346 corresponded to normality, whereas values between 35 and 197 corresponded to disease, in 16 hours. The value found for the Kappa coefficient was 1; the sensitivity and specificity were 100%. Conclusion. It was possible to establish that the mathematical methodology allows to make accurate diagnoses in 16 hours, being proved its applicability in 300 electrocardiographic registers.


Introdução. Com base na teoria de sistemas dinâmicos, foi criada uma lei matemática exponencial que quando aplicada a sistemas cardíacos caóticos permitidos estados Quantificar de normalidade e doença, também é possível encontrar o número total de dinâmica cardíaca de Essa compreensão matemática do fenômeno, neste estudo, avaliou a aplicabilidade clínica e a utilidade diagnóstica da lei exponencial em 300 registros eletrocardiográficos contínuos e estudos Holter, em 16 horas. Material e métodos. A partir de 300 registros eletrocardiográficos contínuos e estudos Holter, dentre os quais 50 apresentaram diagnóstico normal de normalidade e os demais 250 algum tipo de patologia, os mapas de atraso para cada dinâmica cardíaca foram construídos. Em seguida, calculou-se a dimensão fractal e os espaços de ocupação dos atratores. A avaliação matemática foi realizada às 16 e 21 horas, por meio da lei exponencial, e a validação estatística foi realizada. Resultados. Obteve-se que os valores da malha do Kp entre 203 e 346 correspondiam à normalidade, enquanto os valores entre 35 e 197 correspondiam à doença, em 16 horas. O valor encontrado para o coeficiente Kappa foi de 1, a sensibilidade e especificidade foram de 100%. Conclusões. Estabeleceu-se que a metodologia matemática permite realizar diagnósticos precisos em 16 horas, verificando sua aplicabilidade em 300 registros eletrocardiográficos.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...